Files
cti/ics-attack/attack-pattern/attack-pattern--e72425f8-9ae6-41d3-bfdb-e1b865e60722.json
T
2023-11-14 09:18:55 -05:00

63 lines
3.7 KiB
JSON

{
"type": "bundle",
"id": "bundle--80455042-fb91-43d8-abb2-c52db59aab9d",
"spec_version": "2.0",
"objects": [
{
"modified": "2023-10-13T17:57:12.926Z",
"name": "Project File Infection",
"description": "Adversaries may attempt to infect project files with malicious code. These project files may consist of objects, program organization units, variables such as tags, documentation, and other configurations needed for PLC programs to function. (Citation: Beckhoff) Using built in functions of the engineering software, adversaries may be able to download an infected program to a PLC in the operating environment enabling further [Execution](https://attack.mitre.org/tactics/TA0104) and [Persistence](https://attack.mitre.org/tactics/TA0110) techniques. (Citation: PLCdev) \n\nAdversaries may export their own code into project files with conditions to execute at specific intervals. (Citation: Nicolas Falliere, Liam O Murchu, Eric Chien February 2011) Malicious programs allow adversaries control of all aspects of the process enabled by the PLC. Once the project file is downloaded to a PLC the workstation device may be disconnected with the infected project file still executing. (Citation: PLCdev)",
"kill_chain_phases": [
{
"kill_chain_name": "mitre-ics-attack",
"phase_name": "persistence"
}
],
"x_mitre_attack_spec_version": "3.1.0",
"x_mitre_deprecated": false,
"x_mitre_detection": "",
"x_mitre_domains": [
"ics-attack"
],
"x_mitre_is_subtechnique": false,
"x_mitre_modified_by_ref": "identity--c78cb6e5-0c4b-4611-8297-d1b8b55e40b5",
"x_mitre_platforms": [
"None"
],
"x_mitre_version": "1.0",
"x_mitre_data_sources": [
"File: File Modification"
],
"type": "attack-pattern",
"id": "attack-pattern--e72425f8-9ae6-41d3-bfdb-e1b865e60722",
"created": "2020-05-21T17:43:26.506Z",
"created_by_ref": "identity--c78cb6e5-0c4b-4611-8297-d1b8b55e40b5",
"revoked": false,
"external_references": [
{
"source_name": "mitre-attack",
"url": "https://attack.mitre.org/techniques/T0873",
"external_id": "T0873"
},
{
"source_name": "Beckhoff",
"description": "Beckhoff TwinCAT 3 Source Control: Project Files Retrieved. 2019/11/21 ",
"url": "https://infosys.beckhoff.com/english.php?content=../content/1033/tc3_sourcecontrol/18014398915785483.html&id="
},
{
"source_name": "Nicolas Falliere, Liam O Murchu, Eric Chien February 2011",
"description": "Nicolas Falliere, Liam O Murchu, Eric Chien 2011, February W32.Stuxnet Dossier (Version 1.4) Retrieved. 2017/09/22 ",
"url": "https://www.wired.com/images_blogs/threatlevel/2011/02/Symantec-Stuxnet-Update-Feb-2011.pdf"
},
{
"source_name": "PLCdev",
"description": "PLCdev Nicolas Falliere, Liam O Murchu, Eric Chien 2011, February W32.Stuxnet Dossier (Version 1.4) Retrieved. 2017/09/22 Siemens SIMATIC Step 7 Programmer's Handbook Retrieved. 2019/11/21 ",
"url": "http://www.plcdev.com/book/export/html/373"
}
],
"object_marking_refs": [
"marking-definition--fa42a846-8d90-4e51-bc29-71d5b4802168"
]
}
]
}